Soft start

SENTROL-EM3

Description
Soft start controller.
Application
Reduced voltage starting of three phase AC motors.
Phase
Three phase
Rating
8–699 A full load
Motor size
5–600 HP
Input
208/220/230/240, 380/415/440/460/480 VAC

Soft start

Features

Protection

  • 2 millisecond fuses are standard with every SENTROL-EM3.
  • Vbo clamping, integral to the power circuit design, provides transient voltage surge protection for the semiconductors.
  • Natural convection cooling of the integral heatsink chassis allows a 50 °C operating temperature rating at full load without fans or thermal derating.
  • Standard duty units use Class 10 overload relays; high inrush units come standard with a Class 20 overload relay.

Smart

  • Operates from any control input from 95 to 220 VAC, or in line with an existing across-the-line starter.
  • Adjustable starting torque.
  • Adjustable acceleration time.
  • Adjustable deceleration time.
  • LED status indicators.
  • VISI-RAMP output indicator (standard on 150 HP and larger).

Control outputs

  • Seal contact and end-of-ramp auxiliary contacts standard on all units.

Cost effective

  • Low unit cost, low installation cost, no regular maintenance required, no mechanical parts to wear out or replace.

Ratings, dimensions and list prices

208/220/230/240 VAC input, 3-phase, 50/60 Hz

SENTROL-EM3, 208/220/230/240 VAC input, 3-phase, 50/60 Hz
Standard inrush, list priceHigh inrush, list price
Model numberMax FLAMax kW (note 1)Max HPOpen chassisVentilated enclosureOpen chassisVentilated enclosure
18EM3-2-5HP31435$720$930$800$1011
18EM3-2-10HP3281510$860$1137$909$1186
18EM3-2-25HP3633025$1227$1661$1570$2004
18EM3-2-50HP31206050$2481$3201$2865$3771
18EM3-2-75HP317810075$3049$3955$3216$4122
18EM3-2-100HP3233132100$3658$4782$4069$5193
18EM3-2-150HP3342200150$4480$6094$4781$6395
18EM3-2-200HP3466250200$4995$6852$5025$6882

380/415/440/460/480 VAC input, 3-phase, 50/60 Hz

SENTROL-EM3, 380/415/440/460/480 VAC input, 3-phase, 50/60 Hz
Standard inrush, list priceHigh inrush, list price
Model numberMax FLAMax kW (note 1)Max HPOpen chassisVentilated enclosureOpen chassisVentilated enclosure
18EM3-4-5HP3835$580$790$712$922
18EM3-4-10HP314610$720$930$800$1011
18EM3-4-25HP3331525$860$1137$909$1186
18EM3-4-50HP3633050$1227$1661$1570$2004
18EM3-4-75HP3924575$1980$2700$2020$2740
18EM3-4-100HP312160100$2481$3201$2865$3771
18EM3-4-150HP3178100150$3049$3955$3216$4122
18EM3-4-200HP3233132200$3658$4782$4069$5193
18EM3-4-300HP3342200300$4480$6094$4781$6395
18EM3-4-400HP3466250400$4995$6852$5025$6882
18EM3-4-600HPID699500600$6803$10198$6803$10198

Dimensions, inches

Open chassisEnclosure
HP at 230 VHP at 460 VHeightWidthDepthHeightWidthDepth
59.56.55.8714128
5109.56.55.8714128
102510.759.257.2516148
25501210.127.2520169
7518148302412
501001814.1210302412
50H100H2514.8710363012
751502514.8710363012
1002002514.8710423612
150300392710603612
200400482710723612
600482710903620

Notes

  1. kW ratings are calculated for 230 V starters at 230 VAC, and for 460 V starters at 380 VAC.
  2. For 25 HP, 208 VAC motors, use the “High Inrush” starter only.
  3. For use on 380/415 VAC, must specify on order: specify “-3-” and use “-4-” prices and dimensions.
  4. For a high inrush rating, add the suffix “H” to the model number. Example: for a 460 VAC, 100 HP starter with high inrush rating, the correct model number is 18EM3-4-100HP3H.